• STAMICARBON

    STAMICARBON

  • EUROTECNICA

    EUROTECNICA

  • CASALE - The Innovative Touch

    CASALE - The Innovative Touch

  • NIIK - 65 Years On the Cutting Edge of Success

    NIIK - 65 Years On the Cutting Edge of Success

  • SAIPEM - Extraordinary Is Our Everyday

    SAIPEM - Extraordinary Is Our Everyday

My UreaKnowHow

Both username as well as password are capital sensitive.

Latest Round Table Topics

HP SCRUBBER BASKET RUPTURE GROOVE.
Yesterday, 15:54

Triuret Buildup in Urea Crystals Melter
Yesterday, 09:37

Urea Plant Process/Operation Engineer
12.05.2021, 21:44

Best achieved specific consumption
10.05.2021, 04:45

Critical Relative Humidity
07.05.2021, 02:16

Our Sister Websites

 

 

 

 

 

 

 

Statistics

Members:
UreaKnowHow.com: 7100+
UreaKnowHow.com & UreaNet.cn: 13000+
AmmoniaKnowHow.com: 1100+
 
Topics: 2000+
Posts: 9600+
Average posts per topic: 5+
Average posts per day: 2-3
 
Libraries:
Photos: 1200+
Videos: 320+
 
Revamp Guides: 
 
 

Safety Information

Total:
- Safety Risks in Urea Plants: 200+
- Safety Risks in Ammonia Plants: 1200+
 
Specific:
- Ammonia Feed Piping Risks: 10+
- Risks during Turnarounds: 10+
For our complete overview of Safety Risks, Incidents and Near Misses, check out FIORDA

Follow us

LinkedinYoutube

AMMO LASER Leak Detection System: The #1 Safety Measure with a Guaranteed Pay Back Time

Several Safety Risks threaten Urea High Pressure Equipment like high pressures, high temperatures, various kind of corrosion phenomena, crystallization risks, large volumes and release of toxic ammonia in case of a leak.

A significant number of serious incidents with Urea High Pressure Equipment still do occur in our industry and in 50% a failing leak detection system was one of the main causes.

The Risk Register for a 316L Urea Grade Reactor identifies totally 50+ safety risks of which 75% can be prevented by operating a proper leak detection system.

The AMMO LASER Leak Detection System is the most reliable HP Equipment Leak Detection System for loose liners available in the market.

A passive leak detection system is in our view not acceptable anymore today; this is best illustrated with Incident 18-005.

AMMO LASER Leak Detection System: The #1 Safety Measure with a Guaranteed Pay Back Time

The AMMO LASER Leak Detection System has following features:

1.Most reliable system (refer to Risk Register Leak Detection Systems)

2.Monitors directly the complete liner surface

3.Continuously monitors the vacuum pressure and ammonia content

4.Introduces no risks for liner bulging and rupture

5.Works also when the synthesis pressure is low and when the liner sees most stresses (heating up, cooling down) and hence a leak detection system is important

6.Does not restrict the leaking flow and does not built up pressure or introduce risks for backflow (refer to Incident 19-005)

7.Is able to dilute the leak and hence minimize the risk of clogging

8.Enables leak detection also in case the grooves are clogged caused by solids from an earlier leak (no need to flush with steam or condensate)

9.Enables leak detection also in case the grooves are clogged caused by corrosion of carbon steel caused by an earlier leak

10.Enables leak detection also in case only one leak detection hole is present

11.Enables leak detection in case of bad design/fabrication of grooves

12.Enables leak detection in case of no grooves present

13.Is able to distinguish false indication from an ammonia cloud in the atmosphere from a real liner leak.

14.Requires tracing and insulation of only a part of the tubing

15.Can combine one ammonia analyzer for multiple equipment items (even from more urea lines)

16.Gives leak rate and calculates leak size

17.Includes a continuous detection for the presence of any liquid

18.Allows safe and simple introduction of leak detection tracer for pinpointing the leak

19.The AMMO LASER ammonia analyzer is the most accurate and reliable ammonia analyzer as it provides a DCS alarm in case out of order, is ammonia specific and is self-calibrating

20.The AMMO LASER ammonia analyzer can be combined with up to seven other NH3 emission sources monitoring leading to lower ammonia consumption costs

21.Requires no inert gas supply and only a low power consumption

22.Already several successful references since 2017

23.A Guaranteed Pay Back Time resulting from shorter shut down periods as one can find the leak faster, knows the leak size and is able to assure no damage to carbon steel pressure bearing wall

24.Plus a Guaranteed Pay Back Time resulting from lower NH3 consumption figures

25.SAIPEM, as owner and licensor of the Snamprogetti™ Urea Technology, approves the AMMO LASER Leak Detection System for application in all its plants

 

Brochure AMMO LASER Leak Detection System

Saipem approves AMMO LASER Leak Detection System

Why the AMMO LASER Leak Detection System is the most reliable leak detection system ?

Illustration why a passive Leak Detection System is not acceptable anymore ?

Example of backflow in a Pressurized Leak Detection System

Video AMMO LASER Leak Detection SystemNEW

 

Frequently Asked Questions

Q1: Why does one need a proper Leak Detection System ?

Q2: When does one need a proper Leak Detection System ?

Q3: Why is a passive leak detection system not acceptable anymore ?

Q4: Why flushing with steam or condensate is NOT a good practice ?

Q5: Which kind of active leak detection systems exist ?

Q6: What is reason #1 to choose for a vacuum system ?

Q7: What is reason #2 to choose for a vacuum system ?

Q8: How a vacuum system is able to distinguish a false indication from an ammonia cloud in the atmosphere from a real liner leak ?

Q9: What is reason #3 to choose for a vacuum system ?

Q10: What is reason #4 to choose for a vacuum system ?

Q11: What is reason #5 to choose for a vacuum system ?

Q12: What is reason #6 to choose for a vacuum system ?

Q13: What is reason #7 to choose for a vacuum system ?

Q14: How a vacuum system is able to detect clogging in the tubing ?