One of the most common causes of safety valve seat leakage is misalignment. This has numerous root causes. Simple things such as handling & transportation, installation, over operation and other sources of vibration are all contributing factors to misalignment.

At LESER we have thought about this problem and come up with a simple solution. A one-piece spindle design with a PTFE bushing incorporated in the adjusting screw. It has a widely spaced top and bottom guide and shorter guiding length.

This all together leads to better alignment, less friction at the guides and therefore less friction during operation.