NH3-HNO3 neutralization for ammonium nitrate production is a fast and strongly exothermic process, in which inadequate mixing and insufficient heat removal may cause local heat accumulation and thermal-safety concerns. However, for internal draft-tube loop reactors, the coupled effects of reactor geometry and coolant injection on circulation, heat transfer, and local overheating risk remain insufficiently understood. In this work, a two-stage CFD-based engineering optimization strategy was applied to a draft-tube loop reactor. In the first stage, cold-flow simulations were used to screen the draft-tube geometry based on circulation intensity and dead-zone volume. The results showed that reactor hydrodynamics were highly sensitive to geometric parameters. A tube-to-reactor diameter ratio of 0.6 provided the strongest recirculation and the smallest dead-zone fraction, while the most favorable circulation structure was obtained when the draft-tube top was aligned with the top of the reaction zone. In the second stage, the selected configuration was evaluated under reactive hot-state conditions with gas-liquid heat transfer and coolant injection. Increasing coolant flow reduced the peak temperature and suppressed local vapor formation. At a coolant flow-rate ratio of 0.2, the maximum temperature decreased to about 170 °C, indicating a substantially reduced thermal-risk level under the present operating conditions. These results provide engineering guidance for improving circulation organization and thermal-risk control in draft-tube loop reactors for strongly exothermic neutralization systems.
Source: https://www.sciencedirect.com/science/article/abs/pii/S0263876226004594