In 1967 Stamicarbon revolutionized the urea production process with the invention of the HP CO2 Stripper by Mr. Petrus JC Kaasenbrood. The HP CO2 stripper did lead to following three main benefits:
1. the carbamate could be recycled at synthesis pressure so no extra water needed to be added to recycle the carbamate;
2. no medium pressure recirculation section was needed anymore and
3. with the condensation of strip gasses in the high pressure carbamate condenser low pressure steam could be produced, which could be used in the downstream sections leading to a reduction of the steam consumption of a urea plant of about a factor two. At that in times when there was an energy crisis in many parts of the world!
There are many causes that the stripper efficiency is lower, such as:
1. High liquid load
2. Fouling liquid dividers
3. Bad installation liquid dividers
4. High delta-P range liquid dividers
5. Fouling inside tubes
6. CO2 distributor issues
7. Steam side issues
All these causes will be discussed in details in this paper.