The outer shell of a Multi-layered Urea Reactor ruptured while the plant was in operation. The plant made an emergency shutdown, samples were collected, and an investigation carried out to establish the root cause of the failure. The paper explains the detailed analysis performed, along with corrective action implemented and a health assessment for safe working of the equipment. The paper also includes references to similar failures in old multi-layered Urea Reactors subsequently and the mitigation plans to avoid such failures.
2021 Singh Failure Analysis and Field Repair of Urea Reactor Shell Rupture