The EPA SARA Title III and Community Right to Know Act require facilities handling hazardous chemical above defined threshold quantities to have an emergency management solution plan in place. To devise a state-of-the-art chemical emergency plan we need to employ the latest science and innovative technologies. Recently, there has been remarkable progress in the area of chemical sensors. Sensors play an important role as a layer o/protection to keep environment and community safe by detecting the release of hazardous chemical when other layers o/protection fail. In this study, we focus 011 the community protection by introducing a novel patented approach to place optimum number o/sensors on the fence line of the plant-site in such a way that any release/rom identified potential release points is detectable. The technique has been applied to a petrochemical facility with multiple potential release points of ammonia. Ammonia is not only toxic and flammable but also can cause public nuisance because of its irritating and pungent odor. The designed sensor network allows
for early detection of chemical releases, which could help to mitigate the release and do shelter-in- place or evacuation o/the impacted population.
2015 Khajehnajafi Automated Sensor Placement for Industrial Plants – A Case Study on an NH3 Plant
Share this on:
Twitter
LinkedIn
Views: 3